JDE - E1 Web Client ActiveX Controls for Media Object and Grid Export / Import FAIL WITH INTERNET EXPLORER X64



Why 64-bit IE doesn’t work on JDE? Any solution for this?
è 可以使用 64-bit IE,但是因為JDE ActiveX contrls 無法支援64-bit IE,所以用到以下兩個功能時有限制。
n   Media Object
n   Grid Export/Import
 è If you use ActiveX controls, use the 32-bit edition of Internet Explorer instead of the 64-bit edition.

IE10 is another issue we have discussed but no conclusion yet.

è IE10 Support begins with 8.98.4.12


32-bit IE9

64-bit IE9



可以查看以下文件:
A. E1: MOBJ: Working with E1 Web Client ActiveX Controls for Media Object and Grid Export / Import (Doc ID 1056203.1)
It does not matter if you are using a 64-bit Windows OS or not. A 32-bit Internet Explorer browser must be used. ActiveX controls are not yet supported with the 64-bit browser. See Bug 12973392 ACTIVEX CONTROL FAIL WITH INTERNET EXPLORER X64


Manual install / File Location on Server

As an example, files jdeexpimpU.cab or jdewebctlsU.cab, are stored on the JAS server in the following location:

http://<JAS_SERVER_NAME/jde/axctls/

example path on weblogic server
C:\jde_home\SCFHA\targets\<instance>\owl_deployment\webclient.ear\app\webclient.war\axctls

There are two files in the E1 web install directory:
    For 8.95 and below, the files are jdewww/axctls/jdeexpimp.cab (for active x control for import/export) and jdewww/axctls/jdewebctls.cab (for active x control for media objects).
    For 8.96 and above, the file names are jdeexpimpU.cab and jdewebctlsU.cab.
You can find them on the JAS server too, under /webclient/web/axctls.
The ActiveX control install files are OCX files within those cab archives.


  1. 在PY_e1oas01上面 To enable the HTML rich text editor set the value of SupportActiveXIE to FALSE in the jas.ini under the [OWWEB] section or Unselect the "Use ActiveX Controls" check box under the server manager web runtime properties.
  2. Restart PY_e1oas02 to let the change effective
  3. Using 32-bit IE9 connect to PY_e1oas01,可以使用 HTML rich text editor 來新增 Text File
  4. Using 64-bit IE9 connect to PY_e1oas01,可以使用 HTML rich text editor 來新增 Text File - Text3
  5. 相同的設定在 PY_e1oas03上面做一次,在開啟檔案時出現" Internet Explorer 無法顯示網頁"的錯誤訊息,可能需要重新deploy instance來看看,可否解決這個問題。
  6. There are differences in the activeX (RTF) and ADF HTML editor.  Once you switch a file from ActiveX to HTML, there will be a change in the text file format.  This is due to font limitations.  Once a file is converted to HTML, or created via HTML, it will be read only with ActiveX.

因為 Export to excel randomly fails with SupportActiveXIE set to FALSE
When exporting data to Excel using the ALL option, most of the times it does not work, the user receives a blank excel worksheet .This only occurs with Internet Explorer and not on Firefox and is reported with Bug 13391456 GRID EXPORT TO EXCEL FAILS IN NON-ACTIVEX MODE - INTERMITTENT ISSUE and is fixed in Tools Release 8.98.4.7.
所以最好upgrade Tools Release 到8.98.4.12之後,再來試著用 SupportActiveXIE set to FALSE



B. E1: JAS: Web Browser Master Checklist for Internet Explorer (Doc ID 1267490.1)

Internet Explorer Notes on ActiveX Controls:

  •  Internet Explorer 64-bit browser is not supported.  The ActiveX controls are currently only built for use with Internet Explorer 32-bit version provided with a Windows 32-bit or x64 installation.  

C. Bug 12973392 : ACTIVEX CONTROL FAIL WITH INTERNET EXPLORER X64

POTENTIAL WORKAROUNDS
  =====================
  Use 32-bit Internet Explorer browser






D. JD Edwards EnterpriseOne 9.1.X Web Client Support Statement (Doc ID 1487909.1)

For certain functionality, such as Media Objects or Exporting from the Grid to Microsoft Excel, JD Edwards EnterpriseOne uses 32-bit ActiveX controls.  If you use ActiveX controls, use the 32-bit edition of Internet Explorer instead of the 64-bit edition. For more information about 32-bit and 64-bit Internet Explorer, refer to Microsoft Knowledge Base Article #896457.




Grid Export / Import